UT Question

Dear All, I need your support to choose the correct answer of the below question,

Difficulties may be encountered when a “C” scan is made during a shear wave immersion test because:

  1. The velocity shift from longitudinal to shear wave makes calibration uncertain
  2. Slow velocity of shear wave requires slow scan rates
  3. Interface synchronization may not be possible for gating.
  4. Focusing is distorted due to the incident angel

2 Replies

  • Let's remove the ones we know are not correct. 1. The velocities of longitudinal and shear are known so calibration is not a problem. 2. Shear velocity is slower however it is still fast enough for automated c-scans. 3. It is true that interface gating may not be possible since there will not be an entry signal to latch your gate to. I would say this answer is the most correct because the c-scan is determined by your gating parameters. 4. Focusing is consideration for the test but can be determined by calculations.
  • In reply to Brian Frye:

    Many thanks for clarification.
Related
  • UT Question

    Dear All, good afternoon, Please see the below question, and provide me with...
  • RT Question

    Dear All... Good Afternoon... I have question of RT, but I'm not sure...
  • RT Question

    Dear All... Good evening... Please what is correct answer of the below question...
  • UT Question

    Dear All, I need your support to choose the correct answer of the below question...
  • UT QUESTION

    Hi, can any expert help to solve this UT question and show me steps? thanks...